Trane · General troubleshooting
Humidifier not making steam
What is going on
Basic checks when the humidifier will not produce steam.
Likely causes
- Humidifier switched off
- Water saddle valve closed
- Indoor blower not running
- Humidity control not calling
Check in this order
- Turn off power before opening the cabinet.
- Confirm the humidifier is on and the green On/Off light is lit.
- Confirm the water saddle valve is open.
- Confirm the indoor blower is running. The humidifier will not run without it.
- Turn the humidity control to its maximum RH setting to force a call, then lower it to the recommended setting for the outdoor temperature.
- Look at the lights. Solid red Fill or Service light means a fault, see those code entries.
Applies to: EHUMD800ASM00BA, EHUMD800BSMLCBA
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane steam humidifier owner's manual 32-5092-3A, Check the Humidifier Operation, PDF p.10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.