Navien · Combi boiler troubleshooting

No space heating

Navien CH ASME

What is going on

The house is not heating but no error code shows.

Likely causes

  • Set temperature too low
  • Remote off or unit in Stand By
  • 24 hour timer blocking the call
  • Unit busy with a DHW call
  • Heating-side strainer blocked
  • Pre-heating mode on

Check in this order

  1. Raise the heating set temperature on the remote.
  2. Make sure the unit has power at the right voltage, the remote is ON and the heating button is active.
  3. Check the clock and the 24 hour timer blocks.
  4. Wait out a DHW call. Heating is held off during DHW and there is about a 3 minute delay when switching back.
  5. Clean the space heating strainer (remove the clip, wash the screen, refit).
  6. If the pre-heating icon is blinking, heating is in stand by until pre-heat ends.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

More combi boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.41. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.