Navien · Combi boiler troubleshooting
No space heating
What is going on
The house is not heating but no error code shows.
Likely causes
- Set temperature too low
- Remote off or unit in Stand By
- 24 hour timer blocking the call
- Unit busy with a DHW call
- Heating-side strainer blocked
- Pre-heating mode on
Check in this order
- Raise the heating set temperature on the remote.
- Make sure the unit has power at the right voltage, the remote is ON and the heating button is active.
- Check the clock and the 24 hour timer blocks.
- Wait out a DHW call. Heating is held off during DHW and there is about a 3 minute delay when switching back.
- Clean the space heating strainer (remove the clip, wash the screen, refit).
- If the pre-heating icon is blinking, heating is in stand by until pre-heat ends.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.41. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.