Navien · Combi boiler troubleshooting
CH series cleaning the intake air filter
What is going on
The intake air filter sits above the fan, under the intake pipe in the top left of the cabinet. A dirty filter can cause E009/E010 style faults.
Likely causes
- Dust or lint on the intake filter
Check in this order
- Turn off power and gas.
- Remove the screw(s) holding the filter.
- Pull the filter out of the bottom of the intake pipe toward you and take the screen out of its plastic frame.
- Wash it with a toothbrush and water.
- Refit the screen and frame onto the intake pipe.
- If you moved the fan, set it back at an angle into the back corner, then slide it into place.
- Refit the screws.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 7.2 Cleaning the Intake Air Filter p.117. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.