Navien · Combi boiler troubleshooting
Annual maintenance check
What is going on
Check list for the yearly visit at the start of the heating season.
Check in this order
- Turn off power before opening the cabinet.
- Check the condensate drains freely and clean out sediment. Every 6 months pull the condensate hose and clear debris.
- Check air vents and relief valves are not weeping.
- Inspect the whole vent for leaks, clean the vent screens, and make sure nothing blocks the intake or exhaust ends.
- Make sure PVC vent joints are tight. Replace cracked or loose fittings.
- Look at the flame through the burner window: you want a 1/2 to 3/4 in. blue flame. Do not open the burner compartment; if the burner needs cleaning, a Navien-approved tech does it.
- Keep the area clear of combustibles and flammable vapors.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH-180/210/240 ASME Installation Manual (ch-asme-installation-manual-en), Maintenance, p.65. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.