Navien · Combi boiler troubleshooting
No space heating - Navien NCB-H
What is going on
No space heat on a Navien NCB-H combi, but the unit has power and the display is on. This one fools people, because the combi puts domestic hot water first, so the heat can seem dead when someone is running a shower. So start with the simple things like power, set temperature and hot water use. If heating performance has dropped, look at air in the system and the boiler pump. A clogged heating-side filter is the other usual find.
Likely causes
- No power or unit in standby
- Unit is busy making DHW (DHW has priority)
- Restricted heating-side filter
- Set temperature too low
- Air in the heating system or a weak boiler pump
Check in this order
- Check power to the unit and that it is plugged into a grounded 120 V outlet, press the Power button to turn it on
- Raise the space heating set temperature
- Remember heating stops while the unit is making domestic hot water, so close all hot taps and wait
- Clean the space-heating return water filter, isolate and relieve pressure first
- If heating performance has dropped, also check for air in the system and check the boiler pump in Test Mode
- Check the display for any error code
- Call a licensed tech for gas side or sealed-combustion issues
Applies to: Navien NCB-H combi boilers: NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NCB-H User's Information Manual Version 1.0 (April 2024), 5.1 Solving Basic Problems, p.24 and 4.4 Cleaning the Heating Return Water Filter, p.16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.