Navien · Combi boiler troubleshooting

No hot water at the tap

Navien CH ASME

What is going on

Water does not come out hot, or nothing comes out when a hot tap is opened.

Likely causes

  • Shut-off valve on the hot or cold line closed
  • Dirty cold water inlet filter
  • Unit frozen
  • Tap not open enough (needs at least 0.5 GPM)
  • An error code on the remote

Check in this order

  1. Check the remote for a flashing error code and look it up.
  2. Make sure the shut-off valves on the hot and cold lines are open.
  3. Clean the cold water inlet filter.
  4. Open the tap more. The unit needs at least 0.5 GPM to fire.
  5. If the inlet pipe is frozen, thaw it with a hair dryer or heat gun.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

More combi boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.40. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.