Navien · Combi boiler troubleshooting
No hot water at the tap
What is going on
Water does not come out hot, or nothing comes out when a hot tap is opened.
Likely causes
- Shut-off valve on the hot or cold line closed
- Dirty cold water inlet filter
- Unit frozen
- Tap not open enough (needs at least 0.5 GPM)
- An error code on the remote
Check in this order
- Check the remote for a flashing error code and look it up.
- Make sure the shut-off valves on the hot and cold lines are open.
- Clean the cold water inlet filter.
- Open the tap more. The unit needs at least 0.5 GPM to fire.
- If the inlet pipe is frozen, thaw it with a hair dryer or heat gun.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.