Navien · Combi boiler troubleshooting
Hot water not hot enough or too hot
What is going on
DHW temperature is off from what the customer wants.
Likely causes
- Set temperature too low or too high
- Cross-connection between hot and cold lines
Check in this order
- Check the DHW set temperature on the remote (86-120°F normal range, up to 140°F by pressing DHW and Heating together).
- If water is still lukewarm, look for cross plumbing between the cold and hot lines.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Basic Troubleshooting, p.40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.