Navien · Combi boiler troubleshooting

Hot water is cold or turns cold - Navien NCB-H

What is going on

Water at the tap stays cold, or turns cold in the middle of a draw, on a Navien NCB-H combi boiler. Confirm first that the boiler is actually seeing a demand, since these units need a minimum flow before they fire. Anything beyond the basic checks, especially gas or combustion work, should go to a licensed technician.

Likely causes

  • Draw below the 0.5 GPM needed to start DHW
  • Active error code on the unit
  • Clogged cold inlet filter limiting flow

Check in this order

  1. Open the tap wider. The boiler needs at least 0.5 GPM to detect a DHW demand.
  2. Check the front panel for an error code and look it up.
  3. Clean the DHW cold inlet filter after closing the shut-offs.
  4. With the tap open, check Status Information > 15. DHW Flow to see what flow the boiler is reading.
  5. If flow reads fine and it still runs cold, stop and call a licensed tech to look at ignition and gas

Applies to: Navien NCB-H combi boilers: NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H

More combi boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NCB-H User's Information Manual Version 1.0 (April 2024), 5.1 Solving Basic Problems, p.24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.