Navien · Combi boiler troubleshooting
Cleaning the intake air filter
What is going on
A plugged intake filter stops the boiler and brings up code 10. Clean it every 3 to 4 months.
Likely causes
- Dust or pollen on the intake filter
Check in this order
- Turn off power before opening the cabinet.
- Find the filter above the fan, under the intake air duct, top left of the cabinet.
- Remove the one Phillips screw and pull the filter frame out toward you.
- Take the screen out of the plastic frame and clean it with a soft brush and water.
- Refit the screen, put the frame back under the intake duct and refit the screw.
Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Cleaning the Intake Air Filter, p.37. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.