Navien · Combi boiler troubleshooting
CH series E040 outdoor sensor shorted - full check
What is going on
E040 shows when the outdoor sensor reads 122°F (50°C) or more with the boiler on.
Likely causes
- Outdoor sensor wire shorted or connector bad
- Failed outdoor sensor
- Bad PCB
Check in this order
- Turn off power before unplugging connectors or measuring resistance.
- Check the outdoor sensor wiring and plug.
- Test the sensor and replace if bad.
- If the sensor is good, replace the PCB.
Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers
More combi boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.27 40 Error p.107. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.