Zoning with circulators: three space heating zones plus indirect DHW piped to boiler
What is going on
Three space heating zones and one indirect DHW aquastat on the boiler control.
Check in this order
- Review the wiring in Sections B and C (pages 72 and 73).
- Wire the DHW aquastat to Input 1 (J17-1/2).
- Wire space heating thermostats to Inputs 2, 3 and 4.
- Assign Inputs 2, 3 and 4 to PRIORITY 2 and choose the matching heating system type in the Wizard or in the PRIORITY 2 menu.
- Assign Input 1 to PRIORITY 1 so DHW takes precedence.
- Use the factory default DHW and heating system settings, or change them if needed.
Applies to: SVF 500/600 boilers with indirect DHW tank
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SVF 500/600 Series 1 boiler manual, p. 80. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.