Zoning: two space heating zones plus DHW piped directly to boiler

SlimFit Series 3

What is going on

Two heating thermostats on PRIORITY 2 and a DHW aquastat on PRIORITY 1.

Check in this order

  1. Check the 120 VAC outputs (page 60) and 24 VAC inputs (page 52).
  2. Connect space heating thermostats to INPUT 2 and INPUT 3. Keep both assigned to PRIORITY 2.
  3. Connect the DHW aquastat to INPUT 1 and assign INPUT 1 to PRIORITY 1 (factory DHW default).
  4. In the Wizard or the PRIORITY 2 menu, select the matching space heating system type.
  5. Use the factory DHW defaults or change them as needed.

Applies to: SlimFit Series 3 550/750 single boiler

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: SlimFit Series 3 boiler manual, p. 64. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.