Zoning: three space heating zones with circulators (no DHW)
What is going on
Three thermostat zones each with its own circulator, all on PRIORITY 2.
Check in this order
- Check the 120 VAC outputs (page 60) and 24 VAC inputs (page 52) in the wiring section.
- Connect thermostats to P11-4/5, P15-1/2 and P15-3/4.
- Connect circulators to the P2 outputs.
- Confirm inputs 1, 2 and 3 are assigned to PRIORITY 2 (factory default).
- In the Wizard or the PRIORITY 2 menu, select the heating system type that matches the installed system.
Applies to: SlimFit Series 3 550/750 single boiler
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SlimFit Series 3 boiler manual, p. 64. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.