Tankless coil water goes cold or stays lukewarm (water boiler)
What is going on
Domestic hot water from the coil is hot then cold, or never hot enough.
Likely causes
- Mineral scale inside the coil
- Stop-leak coating the outside of the coil
- Mixing valve set wrong
- Hot water flow higher than the coil rating
- Tankless control set too low or differential too wide
Check in this order
- Check and reset the mixing valve.
- Add a flow check valve sized to the coil rating if flow is too high.
- Raise the tankless control setting and lower its differential.
- De-lime or replace a scaled coil.
- If stop-leak was added, pull and clean the coil and drain and flush the boiler.
Applies to: WGO-2 to WGO-9 oil-fired water boilers
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain WGO Series 4 Water Boiler Manual 550-142-331/0225, Troubleshooting p.7. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.