Steam boiler short cycling
What is going on
Burner keeps turning on and off in short bursts.
Likely causes
- Thermostat in a draft or near a heat source
- Thermostat heat anticipator set wrong
- Main or radiator air vents not working (one-pipe) or steam traps failed (two-pipe)
- Pressure limit cut-in or differential set wrong
Check in this order
- Check where the thermostat is mounted. It should be on an inside wall, away from heat and drafts.
- Set the heat anticipator to the current draw of the circuit it controls (primary control or switching relay coil).
- Check the main and radiator vents on one-pipe systems, or the traps on two-pipe systems. Repair or replace bad ones.
- Check the pressure limit. Most one- and two-pipe systems need under 2 psig. Typical cut-in is 1/2 to 1 psi with a 1 psi differential.
- For longer cycles, raise the differential in 1/2 psi steps.
Applies to: SGO-3 to SGO-9 oil-fired steam boilers
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain SGO Series 4 Steam Boiler Manual 550-142-330/0825, Troubleshooting p.7. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.