Some radiators or baseboards stay cold or are noisy
What is going on
Part of the system does not heat or makes noise while the rest is fine.
Likely causes
- Air in the system
- System pressure low (possible leak)
- High limit set too low
Check in this order
- Bleed air at the vents on the radiators or baseboards.
- Check system pressure. If it is low, look for leaks in the boiler and piping before refilling.
- Check the high limit setting and raise it if it is too low (220°F maximum).
Applies to: WTGO-3 to WTGO-9 oil-fired cast iron boilers
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain WTGO Series 4 Boiler Manual 550-142-332/0225, Troubleshooting, p.7. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.