Weil-McLain · Boiler troubleshooting

Some radiators or baseboards stay cold or are noisy

Weil-McLain WTGO Series 4

What is going on

Part of the system does not heat or makes noise while the rest is fine.

Likely causes

  • Air in the system
  • System pressure low (possible leak)
  • High limit set too low

Check in this order

  1. Bleed air at the vents on the radiators or baseboards.
  2. Check system pressure. If it is low, look for leaks in the boiler and piping before refilling.
  3. Check the high limit setting and raise it if it is too low (220°F maximum).

Applies to: WTGO-3 to WTGO-9 oil-fired cast iron boilers

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Weil-McLain WTGO Series 4 Boiler Manual 550-142-332/0225, Troubleshooting, p.7. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.