What is going on
Once the SlimFit is removed from a shared vent, remaining appliances may not vent properly if the flue is oversized. Test each remaining appliance this way.
Likely causes
- Vent oversized for the remaining appliances after the old boiler is removed
Check in this order
- Seal any unused openings in the common vent.
- Visually inspect the vent for correct size, horizontal pitch, blockage, leakage, corrosion or other unsafe conditions.
- Close building doors and windows, and doors to other spaces. Run clothes dryers, non-vented appliances and exhaust fans (range hood, bath) at maximum speed. Do not run a summer exhaust fan. Close fireplace dampers.
- Run one remaining appliance alone with its thermostat calling for continuous operation.
- After 5 minutes of main burner operation, test the draft hood relief opening for spillage using a flame, candle or smoke.
- When each appliance vents correctly, return doors, windows, fans, dampers and other appliances to their normal state.
- If any appliance fails, correct the common vent to meet the National Fuel Gas Code (ANSI Z223.1) or B149.1/B149.2 in Canada, usually by resizing toward the minimum size from the code tables.
Applies to: Existing common vent systems replaced by SlimFit boilers
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SlimFit Series 3 boiler manual 550-100-559/0725, p. 23. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.