Weil-McLain · Boiler troubleshooting
Constant makeup water, black water or popping noise (water boiler)
What is going on
Boiler needs water often, water is black, or the block pops and percolates.
Likely causes
- Leaks in the boiler or piping
- Mineral build-up in the sections from fresh makeup water
- Oxygen corrosion from leaks
- Water pH outside 7.0 to 8.5
Check in this order
- Find and fix leaks first.
- Check pH. Keep it between 7.0 and 8.5.
- If the block pops, de-lime it after the leaks are fixed.
- Do not use petroleum-based stop-leak in the system.
Applies to: WGO-2 to WGO-9 oil-fired water boilers
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain WGO Series 4 Water Boiler Manual 550-142-331/0225, Troubleshooting p.7. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.