Condensate trap check (110/155)

Evergreen Series 2

What is going on

On 110/155 models the condensate trap sits under the boiler with a ball float. The trap must hold water so flue gas cannot enter the room.

Likely causes

  • Dry condensate trap
  • Ball float stuck or missing
  • Blocked or damaged condensate drain tubing

Check in this order

  1. Look at the condensate drain tubing and its end. Make sure it is in good condition and condensate runs freely.
  2. Inspect the condensate trap under the boiler. Make sure the ball float is in place and moves freely.
  3. Make sure the trap has water in it.
  4. If any problem is seen, or the trap is dry, call a boiler service technician immediately.

Applies to: 110/155 Series 2

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Evergreen Series 2 user's information manual, p. 7. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.