Weil-McLain · Boiler troubleshooting
Condensate trap check (110/155)
What is going on
On 110/155 models the condensate trap sits under the boiler with a ball float. The trap must hold water so flue gas cannot enter the room.
Likely causes
- Dry condensate trap
- Ball float stuck or missing
- Blocked or damaged condensate drain tubing
Check in this order
- Look at the condensate drain tubing and its end. Make sure it is in good condition and condensate runs freely.
- Inspect the condensate trap under the boiler. Make sure the ball float is in place and moves freely.
- Make sure the trap has water in it.
- If any problem is seen, or the trap is dry, call a boiler service technician immediately.
Applies to: 110/155 Series 2
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Evergreen Series 2 user's information manual, p. 7. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.