Weil-McLain · Boiler troubleshooting
Boiler shut down by blocked air or vent
What is going on
The control shuts the boiler down when combustion air or vent is blocked and tries to restart within about an hour.
Likely causes
- Blocked combustion air intake
- Blocked vent or flue exhaust
- Debris on air intake or flue openings
Check in this order
- If the blockage is easy to reach and remove, remove it. Clear debris from the air intake and flue exhaust openings.
- Let the boiler try to restart within an hour.
- If the blockage is not obvious or cannot be removed, have a qualified service technician check the boiler and system.
Applies to: 110/155/220/299/300/399 Series 2
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Evergreen Series 2 user's information manual, p. 3, 6. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.