Weil-McLain · Boiler troubleshooting

Automatic air vent check

Evergreen Series 2

What is going on

Applies only to systems with diaphragm-type expansion tanks. Automatic air vents must not be used with other tank types.

Likely causes

  • Air vent stuck or leaking

Check in this order

  1. Remove the cap from the automatic air vent.
  2. Depress the valve pin slightly with a screwdriver tip and check that the vent operates freely without leaking. Water from the vent may be very hot.
  3. Reinstall cap A, twisting it all the way on.
  4. Loosen cap A one turn so the vent can operate.
  5. Have the vent replaced if it does not operate correctly.

Applies to: 110/155/220/299/300/399 Series 2 with diaphragm expansion tank

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Evergreen Series 2 user's information manual, p. 8. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.