Weil-McLain · Boiler troubleshooting

Application B3 piping and circulator requirements

ECO HP

What is going on

Multi-zone space heating with boiler-only DHW, used with the Ultra easy-up manifold. Piping must be primary/secondary. The boiler must sit downstream of the heat pump when they run together, so high return temperatures do not shut the heat pump down. A mixing valve limits DHW temperature. Zone circulators are sized for required flow by the installer. The boiler circulator ships loose with the boiler. The heat pump circulator is in the heat pump manifold.

Likely causes

  • High return temperature to the heat pump if the boiler is upstream of it

Check in this order

  1. Pipe the system primary/secondary.
  2. Place the boiler downstream of the ECO HP.
  3. Install a mixing valve to limit supplied DHW temperature.
  4. Size the zone circulators for the required flow.
  5. Install the boiler circulator (shipped loose with the boiler).
  6. Confirm the heat pump circulator is in the heat pump manifold.

Applies to: Application B3 (Ultra easy-up manifold)

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: ECO HP Heat Pump Application Guide, p. 36. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.