Weil-McLain · Boiler troubleshooting
Annual startup: check the boiler area, air openings and venting
What is going on
Confirm the room and air supply are clear and that the venting is sound before starting the boiler.
Likely causes
- Combustible materials or flammable vapors near the boiler
- Contaminants in the intake air
- Blocked combustion air or vent openings
- Leaking or damaged vent or air piping
Check in this order
- Confirm the boiler area has no combustible materials, gasoline or flammable vapors.
- Confirm the air intake area is free of the contaminants listed on page 24 of the manual. Remove any found. If they cannot be removed, install air and vent lines per the manual and the SlimFit Boiler Vent Supplement.
- Confirm combustion and ventilation openings to the room or building are open and unobstructed. Check automatic combustion air dampers, if used, for operation and wiring.
- Confirm the vent discharge and air intake are clean and clear.
- Inspect the full vent system and any air piping for blockage, deterioration or leaks. Repair leaking joints per the vent manufacturer's instructions.
- If air is ducted to the boiler, confirm the air inlet pipe is connected and sealed.
Applies to: SlimFit 1000-2000 MBH Series 2
More boiler guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: SlimFit Series 2 boiler manual 550-100-561/1225, p. 88. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.