Daikin · Air conditioner troubleshooting

Remove wiring and PS lead on AC models

DX6VS

What is going on

AC 1.5 to 3.0 ton units. Cut the clamps and disconnect the pressure switch (PS) lead and the compressor lead.

Check in this order

  1. Cut the 4 clamps and disconnect the PS lead wire at connector X840A.
  2. When reassembling, fix the PS lead wire in the same position with new clamps.
  3. Remove the 3 clamps and disconnect the compressor lead wire at the U, V, W connector.

Applies to: 1.5 to 3.0 ton AC models

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin sm-sius612209ea service instructions, p. 91. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.