Daikin · Air conditioner troubleshooting

Connect the wireless LAN adapter using WPS

FTXM

What is going on

Used when the home router has a WPS button. The adapter must be connected to the router before the app login is created.

Check in this order

  1. With operation stopped, hold the wireless LAN key for 5 seconds.
  2. Select menu number for WPS and confirm. The adapter lamp blinks faster.
  3. Within about 1 minute, press the WPS button on the router.
  4. Wait until the adapter lamp changes from blinking to lit. That means the connection is complete.
  5. If the lamp turns off, repeat the menu steps and router press.
  6. If it still will not connect, use the procedure without WPS.
  7. Return to the default screen. Continue with the app login step.

Applies to: FTXM09WVJU9, FTXM12WVJU9, FTXM18WVJU9, FTXM24WVJU9

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin FTXM WVJU9 operation manual, p. 37. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.