Clean the air filters
What is going on
Routine filter cleaning, recommended every 2 weeks.
Check in this order
- Open the front panel by the sides.
- Push the filter tab at the center of each air filter up slightly, then pull the filter down and out.
- Vacuum the filters or wash them with water.
- If dust will not come off, wash with neutral detergent in lukewarm water and dry in the shade.
- Reattach the filters.
- Close the front panel slowly and press both sides and the center until it is secure.
Applies to: Air filter
More air conditioner guides
- AC model wiring removal: PS connector, compressor leads and outdoor thermistors
- Check capacitor DC voltage before servicing (1.5 to 5.0 ton outdoor units)
- Clean or replace the titanium apatite deodorizing filters
- Connect the wireless LAN adapter using WPS
- Connect the wireless LAN adapter without WPS
- Cooling analysis: possible causes and remedies
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin Atmosphera operation manual, p. 42. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.