Daikin · Air conditioner troubleshooting

Clean or replace the titanium apatite deodorizing filters

Atmosphera

What is going on

Deodorizing filters sit in a reusable frame behind the air filters.

Likely causes

  • Operating with dirty filters: poor deodorizing and cleaning, poor heating or cooling, possible odor

Check in this order

  1. Open the front panel and remove the air filters.
  2. Hold the frame recesses and unhook the 4 claws, then remove the deodorizing filters from the tabs.
  3. To clean vacuum dust and soak in lukewarm water for about 10 to 15 minutes if very dirty. Do not remove the filter from the frame. Shake off water and dry in the shade. Do not wring it out.
  4. To replace remove the old filter from the frame, fit the new one into the tabs, and keep the frame for reuse.
  5. Dispose of the old filter as non-flammable waste.
  6. Reinstall the filters, reattach the air filters and close the front panel slowly.

Applies to: Titanium apatite deodorizing filter

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin Atmosphera operation manual, p. 43. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.