Daikin · Air conditioner troubleshooting
Connect the wireless LAN adapter without WPS
What is going on
Used when the router has no WPS button or WPS is not used. The adapter creates a link to the router using the SSID and KEY printed on the label.
Check in this order
- With operation stopped, hold the wireless LAN key for 5 seconds.
- Select the menu number and confirm. Adapter lamp blinks for about 1 second.
- Return to the default screen.
- On the smartphone Wi-Fi settings, select the SSID from the unit label and enter the KEY.
- Open the Daikin Comfort Control App and tap the option to configure the wireless connection.
- Select the router SSID, enter its password and connect.
- Check the adapter lamp is lit, not blinking, then tap the continuous-connection option.
- Reconnect the smartphone to the home router over Wi-Fi.
- If connection fails, reset the connection setting to factory default and repeat the steps.
Applies to: FTXM09WVJU9, FTXM12WVJU9, FTXM18WVJU9, FTXM24WVJU9
More air conditioner guides
- AC model wiring removal: PS connector, compressor leads and outdoor thermistors
- Check capacitor DC voltage before servicing (1.5 to 5.0 ton outdoor units)
- Clean or replace the titanium apatite deodorizing filters
- Clean the air filters
- Connect the wireless LAN adapter using WPS
- Cooling analysis: possible causes and remedies
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin FTXM WVJU9 operation manual, p. 38. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.