Rheem · Furnace
Fault recall Power-up replay of the last three faults
What the display is showing
After the furnace control is power-cycled, the seven-segment display replays the three most recent faults younger than one week, newest first, as a diagnostic aid. Faults older than a week drop out of the memory by themselves. Seeing an old code here does not mean the fault is active now.
Applies to: Rheem/Ruud (-)802P / 80MDP 80% two-stage furnaces; R95P furnaces
What to do
- Switch the furnace power off and back on (power reset).
- Watch the seven-segment display up to three stored faults flash one after another, newest first.
- To wipe the history, flip the fault-clear DIP switch (SW8 on the 802P control, SW4 on R95P) six times in a row, alternating, starting from either position, all inside 30 seconds, then put the switch back where it was.
Settings for these units
Clearance to combustibles (all models) · R95P
| Location | Minimum clearance |
|---|---|
| Left side | 0 in. |
| Right side | 0 in. |
| Back | 0 in. |
| Top | 1 in. |
| Front | 2 in. |
| Vent | 0 in. |
| Service (front) | 24 in. recommended |
Same values for R95PA040 through 115.
Column order read from a rotated drawing header - confirm on the furnace clearance label.
Reduced clearance to combustibles, upflow/horizontal (Fig. 4) · Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)
| Model size | Cabinet width (A) | Left side | Right side | Back | Top | Front | Vent |
|---|---|---|---|---|---|---|---|
| 050 (5) | 14 in. | 0 in. | 4 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| 075 (7) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| 100 (10) | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| 125 (12) | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| 150 (15) | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
Note 2: right side may be 0 in. with type B vent.
Note 3: vent clearance may be 1 in. with type B vent.
Models that show this code
11 models in Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC), R95P
Other codes on the same units
- 58 Water sense circuit open
- 59 Water sensed / blocked drain
- C Cooling or heat-pump heat (compressor call)
- F Continuous fan on
- Flame LED slow blink Amber flame LED - marginal flame sense
- Flame LED steady on Amber flame LED steady - normal flame sensed
- H Gas heat on
- h (lowercase) Low-fire gas heat on
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rheem (-)802PA Installation Instructions, Diagnostics and Fault Codes (UT 1028-928 control), pp.40-41; Flame Status LED and Fault Recall (pp.43-44); R95P Fault Recall (printed p.90). Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.