Rheem · Furnace

58 Water sense circuit open

Medium severity R95PR96V/96MDV

What the control is telling you

The electronic water level sensor circuit is open.

Applies to: R95P (R95PA040-115)

Likely causes

  • Water level sensor unplugged or wire broken
  • Faulty water level sensor

Test and repair steps

  1. Check the water level sensor connection at the collector box and its wiring back to the IFC.
  2. Repair broken or loose wiring.
  3. Replace the sensor if the circuit is still open. (Manual gives only the meaning; steps are from general sensor-circuit checks.)

Settings for these units

Clearance to combustibles (all models) · R95P

LocationMinimum clearance
Left side0 in.
Right side0 in.
Back0 in.
Top1 in.
Front2 in.
Vent0 in.
Service (front)24 in. recommended

Same values for R95PA040 through 115.

Column order read from a rotated drawing header - confirm on the furnace clearance label.

Models that show this code

7 models in R95P, R96V/96MDV

96MDV115D50AR95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSA

Other codes on the same units

  • 45 Low pressure switch open - inducer high speed
  • 46 Low pressure switch open - inducer low speed
  • 55 Pressure switch stuck closed
  • 57 Pressure switch stuck open
  • 59 Water sensed / blocked drain
  • 60 Blower fault - running (BLWR FLT-RUN)
  • 66 Blower overspeed (BLOWER OVRSPEED)
  • 68 No blower communication (NO BLWR COMM)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: R95P: Diagnostics and Fault Codes table, p.87 (PDF p.91). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.