Rheem · Furnace
Flame LED steady on Amber flame LED steady - normal flame sensed
What the display is showing
The amber FLAME LED on the integrated furnace control stays continuously lit when the burners are lit and the flame sensor sees a good flame. Off = no flame, slow blink = weak/marginal flame, rapid blink = flame sensed when none should be there. Steady on during the burn is the normal state.
Applies to: Rheem/Ruud (-)802P / 80MDP 80% two-stage furnaces; R95P; Rheem (-)GRC/(-)GTC and 90RJ/90TJ 90 Plus; RGRM/RGTM 90 Plus
Settings for these units
Filter sizes · Rheem RGRM/RGTM 90 Plus
| Cabinet width | Input (MBTUH) | Bottom | Side | Qty |
|---|---|---|---|---|
| 17-1/2 in. upflow | 45, 60, 75A | 15-3/4 x 25 | 15-3/4 x 25 | 1 |
| 21 in. upflow | 75B, 90, 105 | 19-1/4 x 25 | 15-3/4 x 25 | 1 |
| 24-1/2 in. upflow | 120 | 22-3/4 x 25 | 15-3/4 x 25 | 1 |
| 17-1/2 in. downflow/horiz. | 60, 75A | 12 x 20 | - | 2 |
| 21 in. downflow/horiz. | 75B, 90, 105 | 12 x 20 | - | 2 |
| 24-1/2 in. downflow/horiz. | 120 | 14 x 20 | - | 2 |
Use both side returns for 1800 CFM or more.
Some side filters must be trimmed to fit (21 in. cabinets: remove a 3.5 in. strip; 24.5 in.: a 7 in. strip).
Filter sizes (Table 12) · Rheem 90RJ/90TJ 90 Plus
| Configuration | Cabinet width | Input (MBTU/h) | Bottom filter | Side filter | Qty |
|---|---|---|---|---|---|
| Upflow | 17-1/2 in. | 45, 60, 75 | 15-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| Upflow | 21 in. | 90, 105 | 19-1/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| Upflow | 24-1/2 in. | 120 | 22-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| Downflow | 17-1/2 in. | 45, 60, 75 | 12 x 20 in. | - | 2 |
| Downflow | 21 in. | 90, 105 | 12 x 20 in. | - | 2 |
| Downflow | 24-1/2 in. | 120 | 14 x 20 in. | - | 2 |
Filters are not factory-installed; they must be field supplied.
Side filter on 21 in. units: cut 3.5 in. off the filter and frame; on 24.5 in. units cut 7 in.
- Minimum clearance to combustibles · Rheem 90RJ/90TJ 90 Plus
- Filter sizes (Table 9) · Rheem (-)GRC/(-)GTC 90 Plus
- Minimum clearance to combustibles · Rheem (-)GRC/(-)GTC 90 Plus
- Clearance to combustibles (all models) · R95P
- Reduced clearance to combustibles, upflow/horizontal (Fig. 4) · Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)
Models that show this code
44 models in Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC), R95P, Rheem (-)GRC/(-)GTC 90 Plus, Rheem 90RJ/90TJ 90 Plus, Rheem RGRM/RGTM 90 Plus
Other codes on the same units
- C Cooling or heat-pump heat (compressor call)
- CFM LED blinks CFM LED blink count = target airflow
- F Continuous fan on
- Fault recall Power-up replay of the last three faults
- Flame LED off No flame sensed (troubleshooting aid)
- Flame LED slow blink Amber flame LED - marginal flame sense
- H Gas heat on
- Power LED on Power LED on - control has 24 VAC
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: 802PA Flame Status LED (pp.43-44) and Diagnostics flowchart; R95P Flame Status LED (printed p.90); 90RJ and GRC troubleshooting chart (Flame (Amber) LED codes); RGRM Flame LED description p.53. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.