Rheem · Furnace

Flame LED steady on Amber flame LED steady - normal flame sensed

Normal status Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC)R95PRheem (-)GRC/(-)GTC 90 PlusRheem 90RJ/90TJ 90 PlusRheem RGRM/RGTM 90 Plus

What the display is showing

The amber FLAME LED on the integrated furnace control stays continuously lit when the burners are lit and the flame sensor sees a good flame. Off = no flame, slow blink = weak/marginal flame, rapid blink = flame sensed when none should be there. Steady on during the burn is the normal state.

Applies to: Rheem/Ruud (-)802P / 80MDP 80% two-stage furnaces; R95P; Rheem (-)GRC/(-)GTC and 90RJ/90TJ 90 Plus; RGRM/RGTM 90 Plus

Settings for these units

Filter sizes · Rheem RGRM/RGTM 90 Plus

Cabinet widthInput (MBTUH)BottomSideQty
17-1/2 in. upflow45, 60, 75A15-3/4 x 2515-3/4 x 251
21 in. upflow75B, 90, 10519-1/4 x 2515-3/4 x 251
24-1/2 in. upflow12022-3/4 x 2515-3/4 x 251
17-1/2 in. downflow/horiz.60, 75A12 x 20-2
21 in. downflow/horiz.75B, 90, 10512 x 20-2
24-1/2 in. downflow/horiz.12014 x 20-2

Use both side returns for 1800 CFM or more.

Some side filters must be trimmed to fit (21 in. cabinets: remove a 3.5 in. strip; 24.5 in.: a 7 in. strip).

Filter sizes (Table 12) · Rheem 90RJ/90TJ 90 Plus

ConfigurationCabinet widthInput (MBTU/h)Bottom filterSide filterQty
Upflow17-1/2 in.45, 60, 7515-3/4 x 25 in.15-3/4 x 25 in.1
Upflow21 in.90, 10519-1/4 x 25 in.15-3/4 x 25 in.1
Upflow24-1/2 in.12022-3/4 x 25 in.15-3/4 x 25 in.1
Downflow17-1/2 in.45, 60, 7512 x 20 in.-2
Downflow21 in.90, 10512 x 20 in.-2
Downflow24-1/2 in.12014 x 20 in.-2

Filters are not factory-installed; they must be field supplied.

Side filter on 21 in. units: cut 3.5 in. off the filter and frame; on 24.5 in. units cut 7 in.

Models that show this code

44 models in Rheem/Ruud 802P / 80MDP 80% two-stage furnace (UT 1028-928 IFC), R95P, Rheem (-)GRC/(-)GTC 90 Plus, Rheem 90RJ/90TJ 90 Plus, Rheem RGRM/RGTM 90 Plus

90RJ0490RJ0690RJ0790RJ0990RJ1090RJ1290TJ0490TJ0690TJ0790TJ0990TJ1090TJ12R802PA050314MSAR802PA075417MSAR802PA100521MSAR802PA125524MSAR802PA150524MSAR95PA0401317MSAR95PA0601317MSAR95PA0701317MSAR95PA0851521MSAR95PA1001521MSAR95PA1151524MSARGRC-04EMAESRGRC-06EMAESRGRC-07EMAESRGRC-07ERBGSRGRC-09EZAJSRGRC-10EZAJSRGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTC-04EMAESRGTC-06EMAESRGTC-07ERBGSRGTC-09EZAJSRGTC-10ERBJSRGTM-06RGTM-07RGTM-09RGTM-10

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: 802PA Flame Status LED (pp.43-44) and Diagnostics flowchart; R95P Flame Status LED (printed p.90); 90RJ and GRC troubleshooting chart (Flame (Amber) LED codes); RGRM Flame LED description p.53. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.