Rheem · Furnace
CFM LED blinks CFM LED blink count = target airflow
What the display is showing
The CFM LED on the RGRM/RGTM control reports the blower's target airflow by blinking. One full blink is 100 CFM and a half blink is about 50 CFM, followed by a pause of about one second before the count repeats. Example: eleven and a half blinks means roughly 1150 CFM. It is a target value and only a rough guide, not a measurement.
Applies to: Rheem RGRM/RGTM 90 Plus furnaces
What to do
- Watch the CFM LED while the blower is running.
- Count full blinks (100 CFM each) and half blinks (50 CFM each) until the one-second pause.
- Total them for the approximate target CFM.
Settings for these units
Filter sizes · Rheem RGRM/RGTM 90 Plus
| Cabinet width | Input (MBTUH) | Bottom | Side | Qty |
|---|---|---|---|---|
| 17-1/2 in. upflow | 45, 60, 75A | 15-3/4 x 25 | 15-3/4 x 25 | 1 |
| 21 in. upflow | 75B, 90, 105 | 19-1/4 x 25 | 15-3/4 x 25 | 1 |
| 24-1/2 in. upflow | 120 | 22-3/4 x 25 | 15-3/4 x 25 | 1 |
| 17-1/2 in. downflow/horiz. | 60, 75A | 12 x 20 | - | 2 |
| 21 in. downflow/horiz. | 75B, 90, 105 | 12 x 20 | - | 2 |
| 24-1/2 in. downflow/horiz. | 120 | 14 x 20 | - | 2 |
Use both side returns for 1800 CFM or more.
Some side filters must be trimmed to fit (21 in. cabinets: remove a 3.5 in. strip; 24.5 in.: a 7 in. strip).
Models that show this code
10 models in Rheem RGRM/RGTM 90 Plus
Other codes on the same units
- 6 blinks Line and neutral reversed
- Flame LED steady on Amber flame LED steady - normal flame sensed
- Power LED on Power LED on - control has 24 VAC
- Status LED steady on Status LED steady - normal (RGRM/RGTM)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rheem RGRM Installation Instructions (Nature Air), Flame, Status, Power and CFM LED descriptions, p.53. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.