What the display is showing

On the RGRM/RGTM control the STATUS LED lights steady when everything is normal and no fault is stored. Blink counts (1 to 6) replace the steady light when a fault is present; those are listed as the blink codes.

Applies to: Rheem RGRM/RGTM 90 Plus furnaces

Settings for these units

Filter sizes · Rheem RGRM/RGTM 90 Plus

Cabinet widthInput (MBTUH)BottomSideQty
17-1/2 in. upflow45, 60, 75A15-3/4 x 2515-3/4 x 251
21 in. upflow75B, 90, 10519-1/4 x 2515-3/4 x 251
24-1/2 in. upflow12022-3/4 x 2515-3/4 x 251
17-1/2 in. downflow/horiz.60, 75A12 x 20-2
21 in. downflow/horiz.75B, 90, 10512 x 20-2
24-1/2 in. downflow/horiz.12014 x 20-2

Use both side returns for 1800 CFM or more.

Some side filters must be trimmed to fit (21 in. cabinets: remove a 3.5 in. strip; 24.5 in.: a 7 in. strip).

Models that show this code

10 models in Rheem RGRM/RGTM 90 Plus

RGRM-04RGRM-06RGRM-07RGRM-09RGRM-10RGRM-12RGTM-06RGTM-07RGTM-09RGTM-10

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rheem RGRM Installation Instructions (Nature Air), Flame, Status, Power and CFM LED descriptions, p.53. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.