STATUS 2 menu Furnace user menu - STATUS 2
What the display is showing
Communicating-thermostat menu showing MODE (MOD HEAT, AC, FAN ONLY or HP), MOTOR MFGR, MOTOR RPM, MAXIMUM CFM, BLOWER CFM, TEMP DIFF (shown with RISE or DROP), RETURN TEMP, SUPPLY TEMP and HUM OUTPUT. NA means no supply sensor and the sensor option is off; FLT means the sensor is enabled but not sensed. Supply/return readings are unreliable in standby.
Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces
What to do
- Enter the furnace USER MENU from the communicating thermostat.
- Open STATUS 2 and step through the items.
- Read temperatures only while the blower is running.
Settings for these units
Filter sizes as shipped, upflow (Table 19) · RGPE/RGLE
| Cabinet width | Input | Bottom filter | Side filter | Quantity |
|---|---|---|---|---|
| 17-1/2 in. | 50, 75 (000 Btu/h) | 15-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| 21 in. | 75, 100 (000 Btu/h) | 19-1/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| 24-1/2 in. | 125 (000 Btu/h) | 22-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
Use one filter location only - do not double-filter or filter the supply side.
21 in./100K: cut 3-1/2 in. off filter and frame for a side filter; 24-1/2 in./125K: cut 7 in.
Reduced clearance to combustibles (Fig. 3 and 4) · RGPE/RGLE
| Model size | Cabinet width (A) | Left side | Right side | Back | Top | Front | Vent |
|---|---|---|---|---|---|---|---|
| RGPE upflow/horizontal 05 | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 07(A) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 07(B), 10 | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 12 | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 07(A) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 07(B), 10 | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 12 | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
Note 2: right side may be 0 in. with type B vent.
Note 3: vent clearance may be 1 in. with type B vent.
Models that show this code
10 models in RGPE/RGLE
Other codes on the same units
- RX LED blinking Green RX LED - network traffic present
- SEARCHING Thermostat start-up message - searching
- SETUP menu Furnace user menu - SETUP
- STAT LED double blink Red STAT LED - two slow blinks at power-up
- STATUS 1 menu Furnace user menu - STATUS 1
- Top and bottom bars (right digit) Fault history cleared confirmation
- UNIT INFO menu Furnace user menu - UNIT INFO
- cd / Cd Dehumidification cooling
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: RGPE Furnace User Menus, STATUS 2, pp.54-55. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.