Rheem · Furnace
SETUP menu Furnace user menu - SETUP
What the display is showing
Field-adjustment menu on communicating systems: HEAT ADJ (A-D), BLOWER OFF DELAY (A-D), SUPPLY AIR SENS (on/OFF), AC-HP ADJ, ON DEMAND DEHUM, AC HP STG MULT, FIXED FIRE RATE and RESET ALL DFLTS. Changes are kept through power loss. Setting SUPPLY AIR SENS to OFF suppresses fault 82.
Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces
What to do
- Open the furnace USER MENU at the communicating thermostat and select SETUP.
- Scroll to the item and change it with the thermostat keys.
- Exit the menu; values are stored automatically.
Settings for these units
Filter sizes as shipped, upflow (Table 19) · RGPE/RGLE
| Cabinet width | Input | Bottom filter | Side filter | Quantity |
|---|---|---|---|---|
| 17-1/2 in. | 50, 75 (000 Btu/h) | 15-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| 21 in. | 75, 100 (000 Btu/h) | 19-1/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| 24-1/2 in. | 125 (000 Btu/h) | 22-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
Use one filter location only - do not double-filter or filter the supply side.
21 in./100K: cut 3-1/2 in. off filter and frame for a side filter; 24-1/2 in./125K: cut 7 in.
Reduced clearance to combustibles (Fig. 3 and 4) · RGPE/RGLE
| Model size | Cabinet width (A) | Left side | Right side | Back | Top | Front | Vent |
|---|---|---|---|---|---|---|---|
| RGPE upflow/horizontal 05 | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 07(A) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 07(B), 10 | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 12 | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 07(A) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 07(B), 10 | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 12 | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
Note 2: right side may be 0 in. with type B vent.
Note 3: vent clearance may be 1 in. with type B vent.
Models that show this code
10 models in RGPE/RGLE
Other codes on the same units
- HP Heat-pump heat running (dual fuel)
- Learn button Learn button - RX LED rapid blink test
- RX LED blinking Green RX LED - network traffic present
- SEARCHING Thermostat start-up message - searching
- STAT LED double blink Red STAT LED - two slow blinks at power-up
- STATUS 1 menu Furnace user menu - STATUS 1
- STATUS 2 menu Furnace user menu - STATUS 2
- Top and bottom bars (right digit) Fault history cleared confirmation
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: RGPE Furnace User Menus, SETUP, pp.55-56. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.