Rheem · Furnace
STATUS 1 menu Furnace user menu - STATUS 1
What the display is showing
Communicating-thermostat menu with live component states: MAIN LIMIT, MRLC INPUT and HALC INPUT (normal state closed), IDM OUTPUT (OFF/HI/LO), FURN LO PR SW and FURN HI PR SW (OPEN/CLOSED), GAS VLV (firing rate), GAS VLV RELAY (ON/OFF), FLAME (OFF, MARGINAL, GOOD or UNEXPECTED) and BLOWER CFM (requested airflow). Temperatures in user menus are always in Fahrenheit.
Applies to: Rheem/Ruud RGPE / RGLE modulating furnaces
What to do
- Enter the furnace USER MENU using the communicating thermostat (see the thermostat's instructions).
- Choose STATUS 1 and scroll through the items with the arrow keys.
- Exit with the thermostat's back/exit key.
Settings for these units
Filter sizes as shipped, upflow (Table 19) · RGPE/RGLE
| Cabinet width | Input | Bottom filter | Side filter | Quantity |
|---|---|---|---|---|
| 17-1/2 in. | 50, 75 (000 Btu/h) | 15-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| 21 in. | 75, 100 (000 Btu/h) | 19-1/4 x 25 in. | 15-3/4 x 25 in. | 1 |
| 24-1/2 in. | 125 (000 Btu/h) | 22-3/4 x 25 in. | 15-3/4 x 25 in. | 1 |
Use one filter location only - do not double-filter or filter the supply side.
21 in./100K: cut 3-1/2 in. off filter and frame for a side filter; 24-1/2 in./125K: cut 7 in.
Reduced clearance to combustibles (Fig. 3 and 4) · RGPE/RGLE
| Model size | Cabinet width (A) | Left side | Right side | Back | Top | Front | Vent |
|---|---|---|---|---|---|---|---|
| RGPE upflow/horizontal 05 | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 07(A) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 07(B), 10 | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGPE upflow/horizontal 12 | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 07(A) | 17-1/2 in. | 0 in. | 3 in. (note 2) | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 07(B), 10 | 21 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
| RGLE downflow 12 | 24-1/2 in. | 0 in. | 0 | 0 in. | 1 in. | 3 in. | 6 in. (note 3) |
Note 2: right side may be 0 in. with type B vent.
Note 3: vent clearance may be 1 in. with type B vent.
Models that show this code
10 models in RGPE/RGLE
Other codes on the same units
- Learn button Learn button - RX LED rapid blink test
- RX LED blinking Green RX LED - network traffic present
- SEARCHING Thermostat start-up message - searching
- SETUP menu Furnace user menu - SETUP
- STAT LED double blink Red STAT LED - two slow blinks at power-up
- STATUS 2 menu Furnace user menu - STATUS 2
- Top and bottom bars (right digit) Fault history cleared confirmation
- UNIT INFO menu Furnace user menu - UNIT INFO
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: RGPE Furnace User Menus, STATUS 1, pp.52-54. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.