KeepRite heat pump error codes

33 codes (19 faults, 14 normal display and menu codes).

CodeMeaningSeverity / type
16Lost communication with wall controlMedium
25Model plug missing or invalidHigh
31High pressure switch openHigh
32Low pressure switch openHigh
45Outdoor control board failureHigh
46Brown-out (low voltage)Medium
47No 230 V at the unitHigh
53Outdoor air temperature sensor faultMedium
55Outdoor coil sensor faultMedium
56Air and coil sensors disagreeMedium
71Low stage thermal cutoutHigh
72Compressor thermal cutout (two-stage: high stage)High
73Contactor stuck closedHigh
74No 230 V at compressorHigh
81Low stage thermal lockoutHigh
82Thermal lockout (two-stage: high stage)High
83Low pressure lockoutHigh
84High pressure lockoutHigh
Amber 1 flashRunning - cooling / low stage (normal)Normal status
Amber 2 flashesHigh stage running (normal)Normal status
Amber 3 flashesOutdoor fan delay after defrost is on (20 s)Normal status
Amber 4 flashesOutdoor fan delay after defrost is defeatedNormal status
Amber 5 flashesBrown-out protection turned off (user setting)Normal status
Amber 6 flashesBrown-out protection active (user setting)Normal status
Amber LED offStandby - no call (2-wire hookup or indoor unit unpowered)Normal status
Amber LED on solidStandby - no call (communicating)Normal status
Brown-out defeat toggleTurn 230 V brown-out protection off or onMenu / mode display
Defrost speed-up pinsSpeed up the defrost timer for testingMenu / mode display
Fan delay defeat toggleSwitch the post-defrost outdoor fan delay off or onMenu / mode display
Forced defrost pinsForce a defrost cycle / skip the 5-minute delayMenu / mode display
Phase monitor LED flashing3-phase monitor - phase reversalHigh
Phase monitor LED off3-phase monitor - no call for compressorNormal status
Phase monitor LED on3-phase monitor - phases OKNormal status

Models covered

*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960*SH4*SH5*SH6N4H4NXH5R4H4R4H449WCH4

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.