KeepRite heat pump error codes
33 codes (19 faults, 14 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 16 | Lost communication with wall control | Medium |
| 25 | Model plug missing or invalid | High |
| 31 | High pressure switch open | High |
| 32 | Low pressure switch open | High |
| 45 | Outdoor control board failure | High |
| 46 | Brown-out (low voltage) | Medium |
| 47 | No 230 V at the unit | High |
| 53 | Outdoor air temperature sensor fault | Medium |
| 55 | Outdoor coil sensor fault | Medium |
| 56 | Air and coil sensors disagree | Medium |
| 71 | Low stage thermal cutout | High |
| 72 | Compressor thermal cutout (two-stage: high stage) | High |
| 73 | Contactor stuck closed | High |
| 74 | No 230 V at compressor | High |
| 81 | Low stage thermal lockout | High |
| 82 | Thermal lockout (two-stage: high stage) | High |
| 83 | Low pressure lockout | High |
| 84 | High pressure lockout | High |
| Amber 1 flash | Running - cooling / low stage (normal) | Normal status |
| Amber 2 flashes | High stage running (normal) | Normal status |
| Amber 3 flashes | Outdoor fan delay after defrost is on (20 s) | Normal status |
| Amber 4 flashes | Outdoor fan delay after defrost is defeated | Normal status |
| Amber 5 flashes | Brown-out protection turned off (user setting) | Normal status |
| Amber 6 flashes | Brown-out protection active (user setting) | Normal status |
| Amber LED off | Standby - no call (2-wire hookup or indoor unit unpowered) | Normal status |
| Amber LED on solid | Standby - no call (communicating) | Normal status |
| Brown-out defeat toggle | Turn 230 V brown-out protection off or on | Menu / mode display |
| Defrost speed-up pins | Speed up the defrost timer for testing | Menu / mode display |
| Fan delay defeat toggle | Switch the post-defrost outdoor fan delay off or on | Menu / mode display |
| Forced defrost pins | Force a defrost cycle / skip the 5-minute delay | Menu / mode display |
| Phase monitor LED flashing | 3-phase monitor - phase reversal | High |
| Phase monitor LED off | 3-phase monitor - no call for compressor | Normal status |
| Phase monitor LED on | 3-phase monitor - phases OK | Normal status |
Models covered
*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960*SH4*SH5*SH6N4H4NXH5R4H4R4H449WCH4
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.