KeepRite · Heat pump

81 Low stage thermal lockout

High severity KeepRite *CA/*CH Two-Stage Communicating

What the control is telling you

Thermal cutout on 3 cycles in a row; low stage locked out 4 hours or until 24 V is cycled.

Applies to: KeepRite *CA7/*CA9 AC and *CH6/*CH9 HP two-stage communicating

Likely causes

  • Repeated low-stage overload trips - see code 71

Test and repair steps

  1. Fix the code 71 cause.
  2. Cycle 24 V to clear.

Models that show this code

8 models in KeepRite *CA/*CH Two-Stage Communicating

*CH624*CH636*CH648*CH660*CH924*CH936*CH948*CH960

Other codes on the same units

  • 71 Low stage thermal cutout
  • 72 Compressor thermal cutout (two-stage: high stage)
  • 73 Contactor stuck closed
  • 74 No 230 V at compressor
  • 82 Thermal lockout (two-stage: high stage)
  • 83 Low pressure lockout
  • 84 High pressure lockout
  • Amber 1 flash Running - cooling / low stage (normal)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: KeepRite_ICP_KeepRite_Tempstar_Heil_split_A_C_HP_R_410A_R_22_service_421_08_5400_04.txt - section Table 17 Troubleshooting (two-stage). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.