Carrier air conditioner error codes
61 codes (44 faults, 17 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 1 | Normal operation - 1 flash | Normal status |
| 1 long | Capacity limited - one long flash | Normal status |
| 2 | Normal operation - 2 flashes (high stage) | Normal status |
| 4 | Four flashes - speed limiting, non-communicating thermostat | Normal status |
| 5 | Five flashes - brownout protection setting (24ANB/25HNB) | Normal status |
| 6 | Six flashes - brownout protection setting (24ANB/25HNB) | Normal status |
| 16 | Lost communication with user interface | Medium |
| 25 | Invalid model plug / inverter size | High |
| 31 | High pressure switch open | High |
| 32 | Low pressure trip | Medium |
| 33 | Lost inverter communication | Medium |
| 45 | Outdoor control board failure | High |
| 46 | Brownout | Medium |
| 47 | No 230 V at unit | High |
| 48 | Lost inverter communication - lockout | High |
| 49 | Compressor over current | Medium |
| 53 | Outdoor air temperature sensor fault | Medium |
| 54 | Suction temperature sensor fault | Medium |
| 55 | Outdoor coil temperature sensor fault | Medium |
| 56 | OAT / coil thermistor out of range | Medium |
| 57 | Suction pressure transducer fault | Medium |
| 59 | Discharge temperature high (event) | Medium |
| 61 | Fan inverter fault | Medium |
| 63 | Fan inverter current fault | Medium |
| 65 | DC bus voltage low - speed limiting | Medium |
| 66 | Outdoor fan dropped out | Medium |
| 67 | Stator heater fault | Medium |
| 68 | 10-minute stage 2 warm-up delay | Low |
| 69 | Inverter / compressor internal fault | High |
| 71 | Compressor dropped out | Medium |
| 72 | Suction over temperature (event) | Medium |
| 73 | Contactor shorted | High |
| 74 | Discharge temperature lockout | High |
| 75 | Maximum power mode - temperature | Medium |
| 76 | Fan inverter lockout | High |
| 77 | Maximum power mode - compressor current | Medium |
| 79 | Compressor / inverter fault (failed start) | Medium |
| 81 | Low stage thermal lockout | High |
| 82 | Suction over temperature lockout | High |
| 83 | Low pressure lockout (4 hours) | High |
| 84 | High pressure lockout (4 hours) | High |
| 86 | Fan inverter current lockout | High |
| 88 | Compressor / inverter lockout | High |
| 91 | Inverter DC over voltage (event) | Medium |
| 92 | Inverter DC under voltage (event) | Medium |
| 95 | Compressor over current lockout | High |
| 96 | DC under voltage lockout | High |
| 97 | DC over voltage lockout | High |
| 98 | High torque event | Medium |
| 99 | High torque lockout | High |
| LD1 | MOC red LED LD1 (sizes 25-60) | Normal status |
| LD5 | MOC green LED LD5 (sizes 25-60) | Normal status |
| LED1 | MOC red LED1 (sizes 25-60) | Normal status |
| LED3 | MOC amber LED3 (sizes 25-60) | Normal status |
| LED200 | MOC red LED (sizes 13, 24B) | Normal status |
| LED207 | MOC amber LED (sizes 13, 24B) | Normal status |
| COMM LED | Green COMM LED on - communicating | Normal status |
| Charging mode | Refrigerant charging mode (25VNA8/24VNA9, communicating) | Menu / mode display |
| Curtailment | Utility curtailment shown on user interface | Normal status |
| ON | Amber STATUS LED on solid - standby | Normal status |
| Status code recall | Status code recall mode (25VNA8/24VNA9) | Menu / mode display |
Models covered
24ACB724ANB12424ANB13624ANB14824ANB16024ANB72424ANB73624ANB74824ANB76024VNA924VNA91324VNA92424VNA92524VNA93624VNA93724VNA94824VNA94924VNA960CA17DLFULAQ24XAXDLFULAQ24XBXDLFULAQ36XBXDLFULAQ36XCXDLFULAQ48XCXDLFULAQ60XDX
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.