Carrier · Air conditioner
1 Normal operation - 1 flash
What the display is showing
The amber STATUS LED gives one flash and a pause, repeating. This is a normal running indication, not a fault: on the 25VNA8/24VNA9 with an Infinity control it means variable capacity operation, and with a 2-stage thermostat it means low capacity. On the 24ANB/25HNB it means low stage cooling or heating, and on the single-stage communicating heat pump it means normal cooling or heating.
Applies to: Carrier Infinity 25VNA8/24VNA9 variable speed, 24ANB/25HNB two-stage and single-stage communicating outdoor units
Models that show this code
17 models in Carrier Infinity 19VS 24VNA9, Carrier 2-stage 24ANB/25HNB
Other codes on the same units
- 1 long Capacity limited - one long flash
- 2 Normal operation - 2 flashes (high stage)
- 4 Four flashes - speed limiting, non-communicating thermostat
- 5 Five flashes - brownout protection setting (24ANB/25HNB)
- 6 Six flashes - brownout protection setting (24ANB/25HNB)
- 16 Lost communication with user interface
- 25 Invalid model plug / inverter size
- 31 High pressure switch open
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier 25VNA8/24VNA9 service manual, Table 6 Fault Code Actions (status rows), p.15-16; Carrier residential A/C and heat pump service manual 24-25, Table 14 Status Codes (single-stage communicating HP), p.50-51; Carrier residential A/C and heat pump service manual 24-25, Table 18 Troubleshooting (2-stage 24ANB/25HNB), p.60-61. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.