Heat pump downstream of boiler (non-condensing boiler)
What happens, in order
- Heat pump sees high return temperature when the boiler runs.
- The heat pump will likely shut down, so concurrent operation with the boiler is prevented.
- Use this piping order mainly for systems with a heat pump and a non-condensing boiler.
- The boiler may be direct or primary/secondary connected, depending on design intent.
Applies to: Heat pump and non-condensing boiler piping order
More Weil-McLain heat pump sequences
- Configuration walk-through · Startup
- Heat pump upstream of boiler (condensing boiler) · Heating
- Application B1 DHW call and 1-hour limit · Domestic hot water
- Application C3 DHW priority sequence · Domestic hot water
- Application C3: DHW priority operation · Domestic hot water
- System Type B, Application B1: DHW call priority behaviour · Domestic hot water
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: ECO HP Heat Pump Application Guide, p. 9. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.