Trane · Furnace · Startup
Gas heating system start-up (manual gas valve procedure)
What happens, in order
- Set the thermostat to its lowest setting.
- Turn off all electrical power to the unit.
- Remove the front panel to reach the main gas valve.
- Move the gas valve toggle switch to OFF.
- Wait five minutes to clear any gas. If gas is smelled, stop and follow the gas-leak instructions, do not operate the unit.
- Move the gas valve toggle switch to ON.
- Reinstall the front panel and confirm all other panels are secured.
- Turn on electrical power to the unit.
- Set the thermostat to the desired temperature and the fan to AUTO. The unit then runs automatically.
- If the unit does not operate, follow the shutdown procedure to turn off gas and call a service technician or gas supplier.
Timings and thresholds
| Item | Value |
|---|---|
| Wait after gas valve is turned off, before turning it back on | 5 minutes |
Applies to: Gas heating system with automatic ignition (no standing pilot)
More Trane furnace sequences
- First-stage gas heating · Heating
- Heating call sequence of operation · Heating
- Heating sequence of operation · Heating
- Second-stage gas heating (S8X2 only) · Heating
- Cooling and heat pump calls on S8 furnace control · Cooling
- Cooling fan-off delay · Cooling
- Shut off gas to the unit · Standby/shutdown
Related
Trane error codes · Trane tips · Trane parts · All Trane sequences
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: Trane gas heating system owner's information 32-5083-1C-EN, p. 2. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.