Daikin · General · Startup
Power-on and start-up
What happens, in order
- Plug the unit in when the air is clean.
- The odor sensor sets its baseline from the odor level in the first minute.
- The dust/particle lamp shows blue for about the first minute.
- Two quick beeps sound when operation starts.
- The HUM monitor shows dashes for about 30 seconds, then shows the room humidity.
Timings and thresholds
| Item | Value |
|---|---|
| Odor sensor baseline | first 1 minute (approx.) |
| Dust lamp blue period | first 1 minute (approx.) |
| HUM monitor dashes | about 30 seconds |
Codes you may see during this
2 quick beeps; – –; Odor sensor lamp blinking
Applies to: Floor standing unit
Models
More Daikin general sequences
- Heater operation and fan run-on · Heating
- Optional heater accessory staging (DQ-P-70-AH-H) · Heating
- Humidifying filter drying after humidifying stops · Standby/shutdown
- Shutdown for prolonged non-use · Standby/shutdown
- Stopping operation · Standby/shutdown
- AUTO operation switching and monitoring mode · Other
- Damper open and close sequence with ventilator · Other
- Energy Savings mode sampling cycle (out-of-limit intake air) · Other
Related
Take it to the job
Sequences of operation, error codes and tips work offline in the HVACopedia app.
Source: Daikin MCKB70YSAU installation & operation manual, p. 10, p. 11, p. 16. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.