Navien · Heat pump troubleshooting

Multikit app shows no data or graph stopped

Navien NAZ

What is going on

The app is paired but shows no data, or monitoring stopped updating.

Likely causes

  • Module and app not paired properly
  • RS-485 cable between heat pump and module loose or damaged

Check in this order

  1. Re-pair the module with the app.
  2. Power off at the disconnect and wait for the inverter board to discharge before touching wiring or the PCB.
  3. Check the RS-485 connector and reseat it.
  4. Inspect the cable. Replace it if damaged.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 3.4 Troubleshooting, p.26. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.