Navien · Heat pump troubleshooting
Front panel shows Operation Prevention in Progress
What is going on
The heat pump is blocked from running when air or tank water is outside its allowed range. This is normal protection, not a fault.
Likely causes
- Ambient air around the unit is below 41°F (5°C) or above 113°F (45°C).
- Tank water is below 50°F (10°C) or above 149°F (65°C).
Check in this order
- Check the ambient temperature around the unit.
- Check the tank water temperature.
- Wait for conditions to return to range; the heat pump resumes automatically.
Applies to: NWP500 series
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 User's Information Manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.