Navien · Heat pump troubleshooting
IoT module LED red or blinking red
What is going on
Solid red: lost Wi-Fi for 30 seconds in a row. Red blink every 3 seconds: lost the heat pump for 30 seconds in a row while running.
Likely causes
- Wi-Fi signal dropped
- Lost link between module and heat pump
Check in this order
- Press and hold the pairing button to clear the error.
- Start pairing again from the Multikit app if needed.
- Keeps coming back replace the IoT module.
Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 3.4 Troubleshooting, p.26. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.