Air space and ventilation requirements for the heat pump
What is going on
The heat pump on top takes heat from the air through its intake and exhausts cooled, dehumidified air and condensate. Small or poorly ventilated spaces can cool down enough to stop the heat pump or reduce efficiency. Condensation on walls can also cause damage.
Likely causes
- Installation space is small and poorly ventilated.
- Air temperature drops in the space.
Check in this order
- For an unvented installation, provide at least 640 ft³ (18.1 m³) of air space.
- If air exchange is provided, the minimum enclosure is 84 ft³ (2.3 m³).
- Use insulated ducting only, to prevent condensation on the ducts.
- Use duct elbows or flexible ducts on the adapters where space is limited.
Applies to: NWP500-50, NWP500-65, NWP500-80
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 26. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.