Navien · Air handler troubleshooting
TXV coil: low suction pressure, low superheat
What is going on
What causes low suction with low superheat on a TXV coil.
Likely causes
- Low load: low indoor airflow, dirty filter, return air too cold, icing on the indoor coil
- Poor air distribution over the indoor coil
- Wrong indoor/outdoor match on a heat pump (charge balance off between heat and cool)
- Oil trapped in the indoor coil
Check in this order
- Check the filter, blower and airflow first.
- Check for coil icing and return air temperature.
- Check that the coil and outdoor unit are a proper match.
Applies to: NAM24B, NAM36B, NAM36C, NAM48C, NAM59C, NAM59D cased coils with TXV and refrigerant leak sensor
More air handler guides
- Air handler or outdoor unit locks out, or transformer burns out (separate transformers)
- Blower does not run, no heat or no cooling: first checks
- Blower runs nonstop and outdoor unit will not start (leak mitigation)
- Electric heat model: constant torque blower motor not running
- Electric heat model: ECM blower motor not running
- Electric heat model: no 24 V control power
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NAM Series cased coil (24-60K, R454B) Installation and Operation Manual, Additional TXV Troubleshooting p.19. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.