Electric heat short cycles or overshoots the setpoint
What is going on
On thermostats with an adjustable heat anticipator, the setting for this air handler is 0.4. A wrong setting changes how long each heat cycle runs.
Likely causes
- Heat anticipator set too low: short cycling
- Heat anticipator set too high: long cycles, house overshoots then gets cold before the next cycle
Check in this order
- Check if the thermostat has an anticipator (self-setting models have none).
- Set the anticipator to 0.4.
- Run a heat cycle and watch the on time and room temperature swing.
Applies to: NASV/NASS 24B, 36C, 48D, 59D
More air handler guides
- Air handler or outdoor unit locks out, or transformer burns out (separate transformers)
- Blower does not run, no heat or no cooling: first checks
- Blower runs nonstop and outdoor unit will not start (leak mitigation)
- Electric heat model: constant torque blower motor not running
- Electric heat model: ECM blower motor not running
- Electric heat model: no 24 V control power
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NAS Series Air Handler Installation and Operation Manual (24-60K, R-454B), 9 Thermostat Wiring and Connections, p.33. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.