Weil-McLain · Heat pump
Pd Outdoor coil (T3) temperature too high
What the control is telling you
The outdoor coil temperature read by T3 went too high.
Applies to: ECO HP 41/48/55 MBH outdoor unit (ODU)
Likely causes
- Coil cover not removed
- Outdoor coil dirty or blocked
- Not enough room around the unit
- Fan motor failed
Test and repair steps
- Turn off power at the disconnect before opening the unit or touching any wiring.
- Remove the coil cover if it is still on.
- Clean the outdoor coil and clear anything blocking it.
- Check clearances around the unit.
- Check the fan. Replace the fan motor if it is broken.
Models that show this code
3 models in Weil-McLain ECO HP
Other codes on the same units
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump ODU Product Manual 550-100-587/0824, sec. 11.8 Error codes, p.37. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.